  1. Climatic conditions

  1) The recommended installation environment temperature is between -40℃ to 85℃ (-40℉ to 185℉).

  2) Do not install the module in a place where it may be submerged by water.

  ﹡Note: The component mechanical load (including wind and snow pressure) is based on the installation method and installation location.

  The mechanical load must be calculated by a professional installer according to the design requirements of the system.

  2. Installation location selection

  In general, solar modules should be installed in locations that receive the most sunlight throughout the year. In the northern hemisphere,

  The components are best placed facing south, and in the southern hemisphere, the components are best placed facing north. If the component is tilted

  30 degrees from the true south (or true north) direction will lose about 10% to 15% of the power output; if the component is tilted at an angle

  A deviation of 60 degrees from the true south (or true north) direction will lose approximately 20% to 30% of the power output. When choosing a location,

  Avoid shadows caused by trees, buildings or other obstacles on the components. Although the manufacturer has installed the appropriate bypass two

  The pole tube minimizes this loss, but the shadow will still cause a reduction in output power.

  When the battery is used in the photovoltaic power generation system, the battery must be installed correctly, so as to protect the operation of the system

  And to ensure the safe use of users; please follow the battery manufacturer’s instructions on installation, operation and maintenance recommendations

  In general, the battery (or battery pack) should be far away from the main traffic arteries of people and animals;

  While working normally, avoid direct sunlight, rain and snow erosion, while maintaining good ventilation; most batteries are in

  Hydrogen gas is generated during charging, which is easy to explode. Be sure not to light an open flame or create sparks around the battery;

  If the battery is installed outdoors, it must be placed in a specially designed place with good insulation and ventilation performance.

  Do not install the module near open flames or flammable materials.

  Do not install the module in a place where it will be immersed in water or where it is continuously exposed to waterwheels or fountains.